Standard equipment of commercial (1st floor) and administrative (2nd floor) premises – empty premises:
| Commercial premises Offices |
Structural system
• System of reinforced concrete poles, stairs, monolithic ceilings
• Brick construction of external and dividing walls
• Thermally insulated exterior panelling
Glass panes (1st floor)
• Aluminium with glass pane 6-12-6 Float Neutral 1.1 (without foil) combined with glass pane 4-16-4 Climaultra 1.1 (without foil) and sandwich transom window
Windows (2nd floor)
• aluminium with glass pane 4-16-4 Climaultra 1.1 without foil
Ceramic tiles
• Preparation and installation of interior tiles (bathroom, toilet) - plaster
Flooring
• Floor in all rooms: anhydride screed and/or concrete screed
Sanitary fittings and utility networks
• Water supply: combined (steel + plastic)
• Tea kitchen room, toilet: preparation of utilities in accordance with lay-out plan
• Toilet: installed flushing cistern with hanging system for toilet bowl
Electrical installation
• Electrical installations: as per lay-out plant, utility networks are dimensioned for air-conditioning
• Meters: separate measuring of electricity consumption in all non-residential premises
(common area and lift will have separate measuring installed)
• Plugs and power switches: Legrand type or comparable product from other manufacturer
• Data networks: light-current networks – integrated networks for cable TV, internet, telephone, and videophone
• Videophone: 1 device in all separate non-residential premises with remote control of electronic entry door system
Heating
• Central heating: gas boiler room situated on the 2nd floor
• Central heating - networks: combined (steel and plastic)
• Heating units in administrative premises: “KORAD” radiator
• Heating units in commercial premises: floor convector supplemented with “KORAD” radiator
• Meters: separately measured power consumption of in all non-residential premises
Air-conditioning
• All non-residential premises on the 1st and 2nd floor will have pre-arranged plan of networks for installation of SPLIT air-conditioning device. Exterior air-conditioning unit will be installed on the roof of the extension on the north-western part of the building.
HVAC system
• In commercial premises (1st floor), air will be exchanged by HVAC unit installed on the 2nd floor.
Room decorating
• Walls and ceilings of rooms – 2 layers of whitewash white.